MB Sample ID: SA211955

Local Sample ID:MS42-12
Subject ID:SU002306
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002306
Subject Type:Cultured cells
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
MS42-12SA211955FL025856786-M1ACell line
MS42-12SA211955FL02585613C6-leucine+13C6-isoleucineTreatment

Collection:

Collection ID:CO002299
Collection Summary:2x105 cells were plated onto 6-well plates in Plasmax media (5 replicates for each cell type). The day after, fresh media containing 13C6-leucine and 13C6-isoleucine for 27h was applied. Before extraction, cells were counted using CASY cell counter (Omni Life Sciences) using a separate counting plate. After that, cells were washed at room temperature with PBS twice and then kept in a cold bath with dry ice and methanol before adding the metabolite extraction solution.
Sample Type:Cultured cells

Treatment:

Treatment ID:TR002318
Treatment Summary:Cells were cultured in Plasmax media supplemented with 2.5% FBS in the presence of 13C6-leucine and 13C6-isoleucine for 27 hours.

Sample Preparation:

Sampleprep ID:SP002312
Sampleprep Summary:Metabolite extraction solution (50% methanol, 30% acetonitrile, 20% ultrapure water, 5 µM final concentration valine-d8) was added to each well after the washes in PBS following the proportion of 1ml of extraction solution per million cells. The extracts were scraped and mixed at 4°C for 15 min. After final centrifugation at max speed for 15 min at 4°C, the supernatants were transferred into LC-MS vials.

Combined analysis:

Analysis ID AN003629
Analysis type MS
Chromatography type HILIC
Chromatography system Dionex Ultimate 3000 UHPLC
Column SeQuant ZIC-pHILIC
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode UNSPECIFIED
Units peak area

Chromatography:

Chromatography ID:CH002684
Chromatography Summary:Chromatographic separation of polar metabolites was achieved using a Millipore Sequant ZIC-pHILIC analytical column (5 µm, 2.1 × 150 mm) equipped with a 2.1 × 20 mm guard column (both 5 mm particle size) with a binary solvent system. Solvent A was 20 mM ammonium carbonate, 0.05% ammonium hydroxide; Solvent B was acetonitrile. The column oven and autosampler tray were held at 40 °C and 4 °C, respectively. The chromatographic gradient was run at a flow rate of 0.200 mL/min as follows: 0–2 min: 80% B; 2-17 min: linear gradient from 80% B to 20% B; 17-17.1 min: linear gradient from 20% B to 80% B; 17.1-22.5 min: hold at 80% B. Samples were randomized and analysed with LC–MS in a blinded manner with an injection volume was 5 µl. Pooled samples were generated from an equal mixture of all individual samples and analysed interspersed at regular intervals within sample sequence as a quality control.
Instrument Name:Dionex Ultimate 3000 UHPLC
Column Name:SeQuant ZIC-pHILIC
Column Temperature:40
Flow Gradient:0-2 min: 80% B; 2-17 min: linear gradient from 80% B to 20% B; 17-17.1 min: linear gradient from 20% B to 80% B; 17.1-23 min: hold at 80% B.
Flow Rate:0.200 mL/min
Solvent A:100% water; 20 mM ammonium carbonate; 0.05% ammonium hydroxide
Solvent B:100% acetonitrile
Chromatography Type:HILIC

MS:

MS ID:MS003380
Analysis ID:AN003629
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Metabolites were measured with a Thermo Scientific Q Exactive Hybrid Quadrupole-Orbitrap Mass spectrometer (HRMS) coupled to a Dionex Ultimate 3000 UHPLC. The mass spectrometer was operated in full-scan, polarity-switching mode, with the spray voltage set to +4.5 kV/-3.5 kV, the heated capillary held at 320 °C, and the auxiliary gas heater held at 280 °C. The sheath gas flow was set to 55 units, the auxiliary gas flow was set to 15 units, and the sweep gas flow was set to 0 unit. HRMS data acquisition was performed in a range of m/z = 70–900, with the resolution set at 70,000, the AGC target at 1 × 106, and the maximum injection time (Max IT) at 120 ms. Metabolite identities were confirmed using two parameters: (1) precursor ion m/z was matched within 5 ppm of theoretical mass predicted by the chemical formula; (2) the retention time of metabolites was within 5% of the retention time of a purified standard run with the same chromatographic method. Chromatogram review and peak area integration were performed using the Thermo Fisher software Tracefinder 5.0 and the peak area for each detected metabolite was normalized against the total ion count (TIC) of that sample to correct any variations introduced from sample handling through instrument analysis. The normalized areas were used as variables for further statistical data analysis.
Ion Mode:UNSPECIFIED