Return to study ST000435 main page

MB Sample ID: SA021883

Local Sample ID:sample37
Subject ID:SU000456
Subject Type:Animal
Subject Species:Homo sapiens
Taxonomy ID:9606
Species Group:Human

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000685
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo TSQ Quantum Ultra
Column Waters Acquity BEH C18 (150 x 2.1mm,1.7um)
MS Type ESI
MS instrument type Triple quadrupole
MS instrument name Thermo Quantum Ultra
Ion Mode POSITIVE
Units micromolar

Chromatography:

Chromatography ID:CH000497
Chromatography Summary:Plasma samples and amino acid calibration standards were prepared with MassTrak Amino Acid Analysis Solution (AAA) kit from Waters according to instructions with slight modifications for detection on a mass spectrometer. A 10 point standard concentration curve was made from the calibration standard solution to calculate amino acid concentrations in plasma samples. A solution containing U-13C4-L-aspartic acid, U-13C3-L-alanine, U-13C4-L-threonine, U-13C5-L-proline, U-13C5-L-valine, U-13C6-leucine, U-13C6-phenylalanine all from Cambridge Isotope Laboratories, 13C6-tyrosine from Isotec, L-arginine (15N2, 2H2) from MassTrace, norvaline from Sigma dissolved in 0.01N HCl was used as the internal standard solution. Frozen plasma samples were thawed, spiked with internal standard then deproteinized with cold MeOH followed by centrifugation at 10,000 g for 5 minutes prior to derivatization according to MassTrak instructions. The amino acid derivatizing reagent used was 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. High resolution separation was done using an Acquity UPLC system, injecting 1 µl of derviatized solution, with a UPLC BEH C18 1.7 micron 2.1×150 mm column from Waters. Column flow was set to 400 µl/min with a gradient from 99.9%A to 98%B where buffer A is 1% acetonitrile in 0.1% formic acid and buffer B is 100% acetonitrile. A column temp of 43 degrees Celsius and a sample tray temp of 6% Celsius. Mass detection was completed on a TSQ Ultra Quantum from Thermo Finnigan running in ESI positive mode. A scan width of 0.002, scan time of 0.04 seconds per transition mass, collision energy of 25, collision gas pressure of 1.5 mTorr, tube lens value set to 90, monitoring a signature ion of the derivitized amines at m/z 171.04 by selected reaction monitoring.
Instrument Name:Thermo TSQ Quantum Ultra
Column Name:Waters Acquity BEH C18 (150 x 2.1mm,1.7um)
Column Temperature:43
Flow Gradient:from 99.9%A to 98%B
Flow Rate:400 µl/min
Solvent A:99% water/1% acetonitrile; 0.1% formic acid
Solvent B:100% acetonitrile
Chromatography Type:Reversed phase