MB Sample ID: SA094612

Local Sample ID:HFD-BPA13
Subject ID:SU001383
Subject Type:Mammal
Subject Species:Rattus norvegicus
Taxonomy ID:10116
Genotype Strain:Sprague Dawley
Age Or Age Range:240 days
Gender:Male
Animal Animal Supplier:Harlan
Animal Housing:polycarbonate-free caging
Animal Light Cycle:14-hr light and 10-hr dark
Animal Feed:Phytoestrogen Reduced II 18-5 (Ziegler Bros, Inc) or D09100301 (Research Diets, Inc)

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002178 AN002179 AN002180
Analysis type MS MS MS
Chromatography type HILIC HILIC HILIC
Chromatography system Agilent 6495 QQQ Agilent 6495 QQQ Agilent 6495 QQQ
Column Waters XBridge Amide (100 x 4.6mm,3.5um) Waters XBridge Amide (100 x 4.6mm,3.5um) Phenomenex Luna NH2 (150 x 2.1mm,3um)
MS Type ESI ESI ESI
MS instrument type Triple quadrupole Triple quadrupole Triple quadrupole
MS instrument name Agilent 6495 QQQ Agilent 6495 QQQ Agilent 6495 QQQ
Ion Mode POSITIVE NEGATIVE POSITIVE
Units peak intensity peak intensity peak intensity

MS:

MS ID:MS002025
Analysis ID:AN002178
Instrument Name:Agilent 6495 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:For data acquisition through LC/MS analysis, 10 µL of suspended samples were injected and analyzed using a 6495 triple quadrupole mass spectrometer (Agilent Technologies, Santa Clara, CA) coupled to a HPLC system (Agilent Technologies, Santa Clara, CA) via Multiple reaction monitoring (MRM). Source parameters were as follows: Gas temperature- 250°C; Gas flow- 14 l/min; Nebulizer - 20psi; Sheath gas temperature - 350°C; Sheath gas flow- 12 l/min; Capillary - 3000 V positive and 3000 V negative; Nozzle voltage- 1500 V positive and 1500 V negative. Approximately 8–11 data points were acquired per detected metabolite. The data acquired using Agilent mass hunter software and data was analyzed using mass hunter quantitative analysis software.
Ion Mode:POSITIVE
  
MS ID:MS002026
Analysis ID:AN002179
Instrument Name:Agilent 6495 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:For data acquisition through LC/MS analysis, 10 µL of suspended samples were injected and analyzed using a 6495 triple quadrupole mass spectrometer (Agilent Technologies, Santa Clara, CA) coupled to a HPLC system (Agilent Technologies, Santa Clara, CA) via Multiple reaction monitoring (MRM). Source parameters were as follows: Gas temperature- 250°C; Gas flow- 14 l/min; Nebulizer - 20psi; Sheath gas temperature - 350°C; Sheath gas flow- 12 l/min; Capillary - 3000 V positive and 3000 V negative; Nozzle voltage- 1500 V positive and 1500 V negative. Approximately 8–11 data points were acquired per detected metabolite. The data acquired using Agilent mass hunter software and data was analyzed using mass hunter quantitative analysis software.
Ion Mode:NEGATIVE
  
MS ID:MS002027
Analysis ID:AN002180
Instrument Name:Agilent 6495 QQQ
Instrument Type:Triple quadrupole
MS Type:ESI
MS Comments:For data acquisition through LC/MS analysis, 10 µL of suspended samples were injected and analyzed using a 6495 triple quadrupole mass spectrometer (Agilent Technologies, Santa Clara, CA) coupled to a HPLC system (Agilent Technologies, Santa Clara, CA) via Multiple reaction monitoring (MRM). Source parameters were as follows: Gas temperature- 250°C; Gas flow- 14 l/min; Nebulizer - 20psi; Sheath gas temperature - 350°C; Sheath gas flow- 12 l/min; Capillary - 3000 V positive and 3000 V negative; Nozzle voltage- 1500 V positive and 1500 V negative. Approximately 8–11 data points were acquired per detected metabolite. The data acquired using Agilent mass hunter software and data was analyzed using mass hunter quantitative analysis software.
Ion Mode:POSITIVE