Return to study ST001820 main page
MB Sample ID: SA169111
Local Sample ID: | 15 |
Subject ID: | SU001897 |
Subject Type: | Cultured cells |
Subject Species: | Mus musculus |
Taxonomy ID: | 10090 |
Gender: | Not applicable |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002954 | AN002955 | AN002956 |
---|---|---|---|
Analysis type | MS | MS | MS |
Chromatography type | Reversed phase | Reversed phase | HILIC |
Chromatography system | Agilent 1260 | Agilent 1260 | Agilent 1260 |
Column | Agilent Eclipse XDB-C18 (100 x 3.0mm) | Agilent Eclipse XDB-C18 (100 x 3.0mm) | Phenomenex Luna NH2 (150 x 2.1mm,3um) |
MS Type | ESI | ESI | ESI |
MS instrument type | Triple quadrupole | Triple quadrupole | Triple quadrupole |
MS instrument name | Agilent 6490 QQQ | Agilent 6490 QQQ | Agilent 6490 QQQ |
Ion Mode | NEGATIVE | POSITIVE | POSITIVE |
Units | area under the curve | area under the curve | area under the curve |
MS:
MS ID: | MS002744 |
Analysis ID: | AN002954 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of over 337 distinct lipids from over 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | NEGATIVE |
MS ID: | MS002745 |
Analysis ID: | AN002955 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of over 337 distinct lipids from over 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | POSITIVE |
MS ID: | MS002746 |
Analysis ID: | AN002956 |
Instrument Name: | Agilent 6490 QQQ |
Instrument Type: | Triple quadrupole |
MS Type: | ESI |
MS Comments: | Lipid profiling was performed using an Agilent 1260 HPLC coupled to an Agilent 6490 triple quadrupole (QQQ) mass spectrometer (41). Each sample was run through three separate chromatographic conditions (reverse-phase negative mode, reverse-phase positive mode and normal-phase positive mode) for the effective quantification of over 337 distinct lipids from over 28 lipid subclasses, as previously described (41). Individual lipid species were measured by multiple reaction monitoring transitions. |
Ion Mode: | POSITIVE |