Return to study ST001890 main page

MB Sample ID: SA175776

Local Sample ID:1055305369
Subject ID:SU001968
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003066 AN003067 AN003068 AN003069
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) EMD Millipore ZIC-HILIC (100 x 2.1mm,3.5um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units MS count MS count MS count MS count

MS:

MS ID:MS002853
Analysis ID:AN003066
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:POSITIVE
  
MS ID:MS002854
Analysis ID:AN003067
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:NEGATIVE
  
MS ID:MS002855
Analysis ID:AN003068
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:POSITIVE
  
MS ID:MS002856
Analysis ID:AN003069
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Data were acquired on a Thermo Q Exactive HF mass spectrometer for HILIC and a Thermo Q Exactive mass spectrometer for RPLC operated in full MS scan mode. MS/MS data were acquired on quality control samples (QC) consisting of an equimolar mixture of all samples in the study. Data from each mode were independently processed using Progenesis QI software (v2.3) (Nonlinear Dynamics, Durham, NC). Metabolic features from blanks and those that didn’t show sufficient linearity upon dilution in QC samples (r<0.6) were discarded. Only metabolic features present in >2/3 of the samples were kept for further analysis. Inter- and intra-batch variations was were corrected using the LOESS (locally estimated scatterplot smoothing Local Regression) normalization method on QC injected repetitively along the batches (span = 0.75). Missing values were imputed by drawing from a random distribution of low values in the corresponding sample.
Ion Mode:NEGATIVE