MB Sample ID: SA242914

Local Sample ID:OilPalm_Salt_10_07DAT_R1_NEG
Subject ID:SU002518
Subject Type:Plant
Subject Species:Elaeis guineensis Jacq.
Taxonomy ID:NCBI:txid51953

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003953 AN003954
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Shimadzu Nexera X2 Shimadzu Nexera X2
Column Waters Acquity BEH HSS T3 (100 x 2.1mm, 1.8um) Waters Acquity BEH HSS T3 (100 x 2.1mm, 1.8um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Bruker maXis Impact qTOF Bruker maXis Impact qTOF
Ion Mode POSITIVE NEGATIVE
Units Peak intensity Peak intensity

MS:

MS ID:MS003688
Analysis ID:AN003953
Instrument Name:Bruker maXis Impact qTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The rate of acquisition spectra was 3.00 Hz, mass range m/z 70–1200 for the polar fraction analysis and m/z 300–1600 for the lipidic fraction. High-resolution mass spectrometry was used for detection (MaXis 4G Q-TOF MS, Bruker Daltonics) equipped with an electrospray source in positive (ESI-(+)-MS) and negative (ESI-(−)-MS) modes. The settings of the mass spectrometer were as follows: capillary voltage, 3800 V; dry gas flow, 9 L min−1; dry temperature, 200 °C; nebulizer pressure, 4 bar; final plate offset, 500 V. For the external calibration of the equipment, we used a sodium formate solution (10 mM HCOONa solution in 50:50 v:v isopropanol and water containing 0.2% formic acid) injected through a six-way valve at the beginning of each chromatographic run. Ampicillin ([M+H] + m/z 350.1186729 and [M-H]- m/z 348.1028826) was the internal standard for later peak normalization on data analysis.
Ion Mode:POSITIVE
  
MS ID:MS003689
Analysis ID:AN003954
Instrument Name:Bruker maXis Impact qTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The rate of acquisition spectra was 3.00 Hz, mass range m/z 70–1200 for the polar fraction analysis and m/z 300–1600 for the lipidic fraction. High-resolution mass spectrometry was used for detection (MaXis 4G Q-TOF MS, Bruker Daltonics) equipped with an electrospray source in positive (ESI-(+)-MS) and negative (ESI-(−)-MS) modes. The settings of the mass spectrometer were as follows: capillary voltage, 3800 V; dry gas flow, 9 L min−1; dry temperature, 200 °C; nebulizer pressure, 4 bar; final plate offset, 500 V. For the external calibration of the equipment, we used a sodium formate solution (10 mM HCOONa solution in 50:50 v:v isopropanol and water containing 0.2% formic acid) injected through a six-way valve at the beginning of each chromatographic run. Ampicillin ([M+H] + m/z 350.1186729 and [M-H]- m/z 348.1028826) was the internal standard for later peak normalization on data analysis.
Ion Mode:NEGATIVE