Summary of Study ST001181

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000793. The data can be accessed directly via it's Project DOI: 10.21228/M85T13 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files
Study IDST001181
Study TitleChild Health and Development Studies womb to breast cancer F0 metabolomics
Study SummaryWe used high resolution metabolomics to understand DDT-induced alterations of in utero environment and potential health effects. This study measured endogenous metabolites in 397 maternal perinatal serum samples collected during 1959-1967 in the Child Health and Development Studies (CHDS) and assessed associations between metabolites and envrionmental chemical concentrations in maternal serum.
Institute
Emory University
Last NameHu
First NameXin
AddressEmory University Whitehead building (Rm 225), 615 Michael Street
Emailxin.hu2@emory.edu
Phone4047275091
Submit Date2019-05-08
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2019-10-11
Release Version1
Xin Hu Xin Hu
https://dx.doi.org/10.21228/M85T13
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001959
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Dionex Ultimate 3000
Column Thermo Accucore C18 (100 x 2.1mm,2.6um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units Peak area

Chromatography:

Chromatography ID:CH001420
Chromatography Summary:Mass spectral data were collected with a 10-minute gradient on a Thermo QExactive coupled with Dionex Ultimate 3000 (Thermo Fisher, San Diego, CA) set to collect data from m/z 85 to 1275 in positive ionization mode at 70,000 resolution. Three technical replicates were run for each sample using dual chromatography measuring both polarities (positive and negative) with a C18 column (Higgins Analytical, 100x2.1mm, 5uL). The right pump controls the gradient with Solvent A as 100% water, Solvent B as 100% Acetontrile, and Solvent C as 98% water with 2% Formic Acid. The left pump is set up to wash (Acetonitrile with 2% Formic Acid) one of the columns while the other column is running the gradient.
Instrument Name:Thermo Dionex Ultimate 3000
Column Name:Thermo Accucore C18 (100 x 2.1mm,2.6um)
Solvent A:100% water(A), 100% acetontrile(B), 100% water; 2% formic acid©
Solvent B:100% water(A), 100% acetontrile(B), 100% water; 2% formic acid(C)
Chromatography Type:Reversed phase