Summary of Study ST001330
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000909. The data can be accessed directly via it's Project DOI: 10.21228/M8668V This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001330 |
Study Title | Multi-omics of OsGF14b-mediated innate immunity against panicle blast in rice |
Study Summary | In the present study, we used a multi-omics approach to decipher the molecular mechanisms of OsGF14b in governing panicle resistance to Magnaporthe oryzae.Results revealed OsGF14b mediated panicle blast resistance was involved in the activation of auxin and JA signaling pathways, resulting in reprogramming of the phenylpropanoid and diterpenoid pathway. |
Institute | Agro-biological Gene Research Center , Guangdong Academy of Agricultural Sciences |
Last Name | Yan |
First Name | Shijuan |
Address | No. 20 Jinying Road, Tianhe District, Guangzhou City, Guangdong Province, 510640, China. |
shijuan@agrogene.ac.cn | |
Phone | +86-020-38213643 |
Submit Date | 2020-03-13 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Thermo) |
Analysis Type Detail | GC-MS/LC-MS |
Release Date | 2020-12-31 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002216 | AN002217 | AN002218 |
---|---|---|---|
Analysis type | MS | MS | MS |
Chromatography type | GC | Reversed phase | Reversed phase |
Chromatography system | Agilent 7890A | Thermo Dionex Ultimate 3000 | Thermo Dionex Ultimate 3000 |
Column | Agilent DB35-MS (30m x 0.25mm,0.25um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
MS Type | EI | ESI | ESI |
MS instrument type | Single quadrupole | Orbitrap | Orbitrap |
MS instrument name | Agilent 5975 | Thermo Fusion Tribrid Orbitrap | Thermo Fusion Tribrid Orbitrap |
Ion Mode | POSITIVE | POSITIVE | NEGATIVE |
Units | Relative content | Relative content | Relative content |
Chromatography:
Chromatography ID: | CH001626 |
Chromatography Summary: | One µl was taken from each sample and injected into GC-MS at 270°C in a split mode (50: 1) with helium carrier gas (> 99.999% purity) flow set to 1 ml/min, and separated by a DB-35MS UI (30 m × 0.25 mm, 0.25 µm) capillary column. The temperature was isothermal for 4 min at 90°C, followed by an 8°C per min ramp up to 205°C, then held for 2 min, and finally ramped up at a rate of 15°C per min to 310°C, held for 2 min. |
Instrument Name: | Agilent 7890A |
Column Name: | Agilent DB35-MS (30m x 0.25mm,0.25um) |
Chromatography Type: | GC |
Chromatography ID: | CH001627 |
Chromatography Summary: | Firstly, 10 μL of each sample was eluted using a TSS T3 column (100 mm × 2.1 mm containing 1.8 μm diameter particles, Waters) with 0.4 mL/min flow rate. The mobile phase A was water with 0.1% formic acid, and the mobile phase B was ACN with 0.1% formic acid. The compounds were separated by a elution gradient: 1% B was initially firstly maintained for 1 min, then linearly increased to 40% B from 1 to 11 min, to 70% B from 11 to 13 min, then to 99% B from 13 to 15 min, and maintained at 99% B from 15 to 16 min, then linearly decreased to 1% B from 16 to 17 min followed by equilibration at 1% B for 3 min. and the column temperature was set at 40°C. |
Instrument Name: | Thermo Dionex Ultimate 3000 |
Column Name: | Waters Acquity BEH HSS T3 (100 x 2.1mm,1.8um) |
Column Temperature: | 40°C |
Flow Rate: | 0.4 mL/min |
Solvent A: | 100% water; 0.1% formic acid |
Solvent B: | 100% acetonitrile; 0.1% formic acid |
Chromatography Type: | Reversed phase |