Summary of Study ST001663
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001069. The data can be accessed directly via it's Project DOI: 10.21228/M8HQ3X This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST001663 |
Study Title | E.coli K-12 treated by IPL - analysis of polar phase (part-I) |
Study Summary | E.coli K-12 cells were treated by IPL, extracted and separated into organic/lipid phase and polar phase. The polar phase was analyzed by HILIC-MS, in both positive and negative ionization mode. |
Institute | University of Minnesota |
Last Name | Chen |
First Name | Chi |
Address | 1334 Eckles Ave, St Paul, Minnesota, 55108, USA |
chichen@umn.edu | |
Phone | 6126247704 |
Submit Date | 2021-01-25 |
Raw Data Available | Yes |
Raw Data File Type(s) | raw(Waters) |
Analysis Type Detail | LC-MS |
Release Date | 2021-02-17 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN002714 | AN002715 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Waters Acquity | Waters Acquity |
Column | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | QTOF | QTOF |
MS instrument name | Waters Xevo-G2-S | Waters Xebo-G2-S |
Ion Mode | POSITIVE | NEGATIVE |
Units | no applicable unites | no applicable unites |
Chromatography:
Chromatography ID: | CH002003 |
Instrument Name: | Waters Acquity |
Column Name: | Waters Acquity BEH Amide (150 x 2.1mm,1.7um) |
Chromatography Type: | HILIC |