This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001080. The data can be accessed directly via it's Project DOI: 10.21228/M83H5W This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001681
Study TitleIntegrated trajectories of the maternal metabolome, proteome, and immunome predict labor onset
Study SummaryEstimating the time of delivery is of high clinical importance as pre- and post-term deviations are associated with complications for the mother and her offspring. However, current estimation approaches are inaccurate. As pregnancy progresses towards labor, major transitions occur in fetomaternal immune, metabolic, and endocrine systems that culminate in the delivery of the fetus. The comprehensive characterization of metabolic, proteomic and immune cell events that precede the spontaneous onset of labor is a key step to understanding these physiological transitions and identifying predictive biomarkers of parturition. Here, over 7,000 circulating plasma analytes and peripheral immune cell responses collected during the last 100 days of pregnancy were integrated into a multi-omic model that accurately predicted the time to spontaneous onset of labor (R = 0.85, p-value = 1.2e-40, training set; R = 0.81, p-value = 3.9e-7, independent test set). Coordinated fluctuations marked a molecular shift from pregnancy progression to pre-labor onset biology 2–4 weeks before delivery. Our study lays the groundwork for developing blood-based methods for predicting the onset of labor, anchored in mechanisms shared in preterm, term, and postterm pregnancies.
Institute
Stanford University
Last NameContrepois
First NameKevin
Address1291 Welch rd, Biomedical innovations building-Room 4400, STANFORD, California, 94305, USA
Emailkcontrep@stanford.edu
Phone6506664538
Submit Date2021-02-02
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2021-07-22
Release Version1
Kevin Contrepois Kevin Contrepois
https://dx.doi.org/10.21228/M83H5W
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002742 AN002743 AN002744 AN002745
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) SeQuant ZIC-HILIC (100 x 2.1mm,3.5um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um) Agilent Zorbax SBaq (50 x 2.1mm,1.7um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units MS Counts MS Counts MS Counts MS Counts

Chromatography:

Chromatography ID:CH002026
Chromatography Summary:HILIC experiments were performed using a ZIC-HILIC column 2.1x100 mm, 3.5μm, 200Å (Merck Millipore) and mobile phase solvents consisting of 10mM ammonium acetate in 50/50 acetonitrile/water (A) and 10 mM ammonium acetate in 95/5 acetonitrile/water (B).(Contrepois et al., 2015)
Instrument Name:Thermo Vanquish
Column Name:SeQuant ZIC-HILIC (100 x 2.1mm,3.5um)
Column Temperature:40
Flow Rate:0.5 ml/min
Solvent A:95% acetonitrile/5% water; 10 mM ammonium acetate
Solvent B:95% acetonitrile/5% water; 10 mM ammonium acetate
Chromatography Type:HILIC
  
Chromatography ID:CH002027
Chromatography Summary:RPLC experiments were performed using a Zorbax SBaq column 2.1 x 50 mm, 1.7 μm, 100Å (Agilent Technologies) and mobile phase solvents consisting of 0.06% acetic acid in water (A) and 0.06% acetic acid in methanol (B). (Contrepois et al., 2015)
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Agilent Zorbax SBaq (50 x 2.1mm,1.7um)
Column Temperature:60
Flow Rate:0.6 ml/min
Solvent A:100% water; 0.06% acetic acid
Solvent B:100% methanol; 0.06% acetic acid
Chromatography Type:Reversed phase