Summary of Study ST001882

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001186. The data can be accessed directly via it's Project DOI: 10.21228/M8DD61 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001882
Study TitleLC-MS for Predator Cues Target Signaling Pathways in Toxic Algal Metabolome Protocol
Study SummaryMetabolomics investigation of the phytoplankton Alexandrium minutum with and without copepod cues in order to explore cell signaling involved in toxin induction.
Institute
Georgia Institute of Technology
Last NameBrown
First NameEmily
Address950 Atlantic Drive, Atlanta GA 30332
Emailemily.brown@gatech.edu
Phone404-894-8424
Submit Date2021-07-15
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2021-07-27
Release Version1
Emily Brown Emily Brown
https://dx.doi.org/10.21228/M8DD61
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003042 AN003043 AN003044 AN003045
Analysis type MS MS MS MS
Chromatography type HILIC HILIC Reversed phase Reversed phase
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Waters Acquity BEH HILIC (150 x 2.1mm,1.7um) Waters Acquity BEH HILIC (150 x 2.1mm,1.7um) Thermo Accucore C30 (150 x 2.1mm,2.6um) Thermo Accucore C30 (150 x 2.1mm,2.6um)
MS Type ESI ESI ESI ESI
MS instrument type Orbritrap/ion trap Orbritrap/ion trap Orbitrap Orbitrap
MS instrument name Thermo Orbitrap ID-X Tribrid Thermo Orbitrap ID-X Tribrid Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units peak area peak area peak area peak area

Chromatography:

Chromatography ID:CH002255
Chromatography Summary:Polar HILIC separation
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH HILIC (150 x 2.1mm,1.7um)
Chromatography Type:HILIC
  
Chromatography ID:CH002256
Chromatography Summary:non-Polar reverse phase separation
Instrument Name:Thermo Vanquish
Column Name:Thermo Accucore C30 (150 x 2.1mm,2.6um)
Chromatography Type:Reversed phase