Summary of Study ST002146

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001360. The data can be accessed directly via it's Project DOI: 10.21228/M8XD72 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002146
Study TitleMetabolomic differences detected in C57BL/6 mice
Study SummaryMice were euthanized at 20 weeks of age, and various tissues were obtained for metabolomic analyses including whole bone, bone marrow, and isolated cortical bone. Metabolites were extracted and underwent LC-MS analysis using an Agilent LC 1290 coupled to an Agilent 6538 QTOF
Institute
Montana State University
Last NameWelhaven
First NameHope
AddressCulbertson Hall, 100
Emailhwelhaven@gmail.com
Phone4066961526
Submit Date2022-04-21
Num Groups2
Total Subjects20
Num Males10
Num Females10
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2022-05-09
Release Version1
Hope Welhaven Hope Welhaven
https://dx.doi.org/10.21228/M8XD72
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003515
Analysis type MS
Chromatography type HILIC
Chromatography system Agilent 6538
Column Cogent Diamond Hydride HILIC (150 × 2.1 mm)
MS Type ESI
MS instrument type Single quadrupole
MS instrument name Agilent 6538 QTOF
Ion Mode POSITIVE
Units Peak Intensiy

Chromatography:

Chromatography ID:CH002595
Chromatography Summary:Samples were analyzed using an Agilent 1290 UPLC coupled to an Agilent 6538 QTOF. All samples were run in normal phase using a Cogent Diamond Hydride HILIC column (150 x 2.1 mm). Solvents: 0.1% formic acid in water (A), 0.1% formic acid in acetonitrile (B). Elution gradient: 100 to 25% solvent B over 17 minutes, 0 to 70% solvent A over 20 minutes, at 21 minutes, B increases from 25% to 100% till 25 minutes while A decreases from 70% to 0% till 25 minutes. The last 4 minutes act as a wash. Total run time = 25 minute method (per sample)
Instrument Name:Agilent 6538
Column Name:Cogent Diamond Hydride HILIC (150 × 2.1 mm)
Flow Gradient:100 to 25% solvent B over 17 minutes, 0 to 70% solvent A over 20 minutes, at 21 minutes, B increases from 25% to 100% till 25 minutes while A decreases from 70% to 0% till 25 minutes. The last 4 minutes act as a wash.
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:HILIC
  logo