Summary of Study ST002332

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001496. The data can be accessed directly via it's Project DOI: 10.21228/M8BX3F This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002332
Study TitlePlasma metabolomic profiling of individuals with autism spectrum disorder and their family members.
Study SummaryAutism spectrum disorder (ASD) is a common neurodevelopmental condition affecting 2.3% of 8-year-old children and is attributable to polygenic risks in most cases. Gene discovery studies catalogued >1000 genes with de novo, rare and common genetic variants that are likely associated with ASD; however, the candidate genes are rarely translated to diagnostic and treatment biomarkers. As such no pharmacological treatment option is available for targeting core symptoms. Neural circuits involved in verbal/nonverbal communications and social interaction are likely changed, which may be caused by an excitatory-inhibitory (E-I) imbalance in individuals with ASD. To date, clinical trials targeting excitatory glutamatergic or inhibitory GABAergic receptors showed mixed results. These early clinical trials highlight the unmet need of biomarkers for target populations and outcome indicators. We investigated whether plasma biomarkers would be associated with genetic risk factors and core symptoms of ASD. Plasma samples were collected for metabolomics profiling from the Autism Genetics Resource Exchange (AGRE). Detailed phenotype information is available at NIMH Data Archive (Collection ID: 4214) and can be accessed using NDAR GUID for the individuals.
Institute
Boston Childrens Hospital
DepartmentComputational Health informatics Program
LaboratoryKong Lab
Last NameKong
First NameSek Won
Address401 Park Drive, LM5528.4
Emailsekwon.kong@childrens.harvard.edu
Phone6179192689
Submit Date2022-10-14
Raw Data AvailableYes
Raw Data File Type(s)mzXML
Analysis Type DetailLC-MS
Release Date2023-10-14
Release Version1
Sek Won Kong Sek Won Kong
https://dx.doi.org/10.21228/M8BX3F
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003806 AN003807
Analysis type MS MS
Chromatography type HILIC Reversed phase
Chromatography system Dionex UltiMate 3000 Dionex UltiMate 3000
Column Waters XBridge BEH Amide XP HILIC (50 x 2.1mm,2.5um) Product #186006089; Thermo Accucore HILIC guard with holder,Product # 17526-012105 Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area peak area

Chromatography:

Chromatography ID:CH002816
Chromatography Summary:The HILIC column is operated parallel to reverse phase column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10- port and 6-port switching valves. During operation of HILIC separation method, the MS is operated in positive ion mode and 10 μL of sample is injected onto the HILIC column while the reverse phase column is flushing with wash solution. Flow rate is maintained at 0.35 mL/min until 1.5 min, increased to 0.4 mL/min at 4 min and held for 1 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 2% formic acid (v/v) in LC-MS grade water. Initial mobile phase conditions are 22.5% A, 75% B, 2.5% C hold for 1.5 min, with linear gradient to 77.5% A, 20% B, 2.5% C at 4 min, hold for 1 min, resulting in a total analytical run time of 5 min. During the flushing phase (reverse phase analytical separation), the HILIC column is equilibrated with a wash solution of 77.5% A, 20% B, 2.5% C.
Methods Filename:EmoryUniversity_HRM-QEHF_chromatography_5min_092017_v1.pdf
Instrument Name:Dionex UltiMate 3000
Column Name:Waters XBridge BEH Amide XP HILIC (50 x 2.1mm,2.5um) Product #186006089; Thermo Accucore HILIC guard with holder,Product # 17526-012105
Column Temperature:60
Solvent A:100% water
Solvent B:100% acetonitrile
Chromatography Type:HILIC
  
Chromatography ID:CH002817
Chromatography Summary:The C18 column is operated parallel to the HILIC column for simultaneous analytical separation and column flushing through the use of a dual head HPLC pump equipped with 10-port and 6- port switching valves. During operation of the C18 method, the MS is operated in negative ion mode and 10 μL of sample is injected onto the C18 column while the HILIC column is flushing with wash solution. Flow rate is maintained at 0.4 mL/min until 1.5 min, increased to 0.5 mL/min at 2 min and held for 3 min. Solvent A is 100% LC-MS grade water, solvent B is 100% LC-MS grade acetonitrile and solvent C is 10mM ammonium acetate in LC-MS grade water. Initial mobile phase conditions are 60% A, 35% B, 5% C hold for 0.5 min, with linear gradient to 0% A, 95% B, 5% C at 1.5 min, hold for 3.5 min, resulting in a total analytical run time of 5 min. During the flushing phase (HILIC analytical separation), the C18 column is equilibrated with a wash solution of 0% A, 95% B, 5% C until 2.5 min, followed by an equilibration solution of 60% A, 35% B, 5% C for 2.5 min.
Methods Filename:EmoryUniversity_HRM-QEHF_chromatography_5min_092017_v1.pdf
Instrument Name:Dionex UltiMate 3000
Column Name:Higgins endcapped C18 stainless steel (50 x 2.1mm,3um),Product #TS-0521-C183; Thermo Accucore C18 guard with holder,Product #17126-014005
Column Temperature:60
Solvent A:100% water
Solvent B:100% acetonitrile
Chromatography Type:Reversed phase
  logo