Summary of Study ST000100

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000092. The data can be accessed directly via it's Project DOI: 10.21228/M81S38 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000100
Study TitleGlobal Metabolomics of C. elegans using an augmented reference IROA design
Study Typeheat shock
Study SummaryGlobal Metabolomics of C. elegans using an augmented reference IROA design
Institute
University of Florida
DepartmentBiochemistry & Molecular Biology
LaboratoryArthur Edison
Last NameEdison
First NameArthur
AddressR3-226 Academic Research Building, Department of Biochemistry & Molecular Biology, PO Box 100245, Gainesville, FL 32610-0245
Emailaedison@ufl.edu
Submit Date2014-09-13
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Uploaded File Size16 G
Analysis Type DetailLC-MS
Release Date2015-02-03
Release Version1
Arthur Edison Arthur Edison
https://dx.doi.org/10.21228/M81S38
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000165 AN000166
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column Waters Acquity HSS T3 (100 x 2.1mm,1.8um) Waters Acquity HSS T3 (100 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units

MS:

MS ID:MS000134
Analysis ID:AN000165
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q-Exactive was equipped with a Heated Electrospray Ionization (HESI) source which operated at a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and auxiliary gas flow rates of 50 and 10 arbitrary units, respectively. The capillary temperature was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution was set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm.
Ion Mode:POSITIVE
Capillary Temperature:325 ?C
Ion Source Temperature:350 ?C
Ion Spray Voltage:3.5 kV
Resolution Setting:70000
  
MS ID:MS000135
Analysis ID:AN000166
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The Q-Exactive was equipped with a Heated Electrospray Ionization (HESI) source which operated at a spray temperature of 350 ?C, a spray voltage of 3.5 kV, and sheath and auxiliary gas flow rates of 50 and 10 arbitrary units, respectively. The capillary temperature was held at 325 ?C, and the S-lens RF Level was set to 40%. The FR resolution was set to 70,000 at m/z 200. The accuracy achieved was routinely less than 1.5 ppm.
Ion Mode:NEGATIVE
Capillary Temperature:325 ?C
Ion Source Temperature:350 ?C
Ion Spray Voltage:3.5 kV
Resolution Setting:70000
  logo