Summary of Study ST000357

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000285. The data can be accessed directly via it's Project DOI: 10.21228/M82W27 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000357
Study TitleBroad Spectrum MS analysis of mouse hypothalmus from Anxiety Prone HSV-Latently Infected Obese Mice
Study TypeBroad Spectrum LCMS
Study SummaryBrain tissue samples for metabolomics experiments were generated in the following manner: 3-week old mice were placed on a 10% low fat (LF) diet and acclimated for one week prior to intranasal HSV-1 infection or mock infection with PBS. Fourteen days post-infection mice were randomized to either a 45% high fat diet (HF) or remained on the LF diet. Eight weeks post-diet transition, mice were euthanized and brain tissue samples were collected and processed for metabolomics.
Institute
University of North Carolina
DepartmentDiscovery Sciences
LaboratorySumner Lab
Last NameSumner
First NameSusan
AddressEastern Regional Comprehensive Metabolomics Resource Core, UNC Nutrition Research Institute, 500 Laureate Way, Kannapolis, NC, 28081
Emailsusan_sumner @unc.edu
Phone704-250-5066
Submit Date2016-03-03
Num Groups4
Total Subjects31
Num Males31
Raw Data AvailableYes
Raw Data File Type(s)raw(Waters)
Analysis Type DetailLC-MS
Release Date2017-03-03
Release Version1
Susan Sumner Susan Sumner
https://dx.doi.org/10.21228/M82W27
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN000584 AN000585
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Synapt G2 Si ESI-Q-TOF Synapt G2 Si ESI-Q-TOF
Column Waters ACQUITY UPLC HSS T3 Waters ACQUITY UPLC HSS T3
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Waters Synapt G2 Si QTOF Waters Synapt G2 Si QTOF
Ion Mode POSITIVE NEGATIVE
Units intensity intensity

MS:

MS ID:MS000520
Analysis ID:AN000584
Instrument Name:Waters Synapt G2 Si QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:POSITIVE
  
MS ID:MS000521
Analysis ID:AN000585
Instrument Name:Waters Synapt G2 Si QTOF
Instrument Type:QTOF
MS Type:ESI
Ion Mode:NEGATIVE