Summary of Study ST001297

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000878. The data can be accessed directly via it's Project DOI: 10.21228/M86D7J This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001297
Study TitleHigh Cellulose diet impact on gut inflammation
Study SummaryDietary cellulose prevents gut inflammation by modulating lipid metabolism and gut microbiota
Institute
Asan Medical Center
Last NameYoo
First NameHyun Ju
Address88, Olympic-ro, 43-gil, Songpa-gu, Seoul 05505, South Korea
Emailyoohyunju@amc.seoul.kr
Phone82-02-3010-4029
Submit Date2019-12-30
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2020-01-06
Release Version1
Hyun Ju Yoo Hyun Ju Yoo
https://dx.doi.org/10.21228/M86D7J
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002158 AN002159 AN002160 AN002161
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000 Thermo Dionex Ultimate 3000
Column Pursuit C18 (150 x 2.1mm) Pursuit C18 (150 x 2.1mm) Zorbax HILIC plus (100 x 2.1mm,3.5um) Zorbax HILIC plus (100 x 2.1mm,3.5um)
MS Type ESI ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE POSITIVE NEGATIVE
Units cps cps cps cps

MS:

MS ID:MS002007
Analysis ID:AN002158
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Xcaliber
Ion Mode:POSITIVE
  
MS ID:MS002008
Analysis ID:AN002159
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Xcaliber
Ion Mode:NEGATIVE
  
MS ID:MS002009
Analysis ID:AN002160
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Xcaliber
Ion Mode:POSITIVE
  
MS ID:MS002010
Analysis ID:AN002161
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Xcaliber
Ion Mode:NEGATIVE