Summary of Study ST002568

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001655. The data can be accessed directly via it's Project DOI: 10.21228/M8S726 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002568
Study TitleAssessment of metabolic changes in different animal models of maladaptive right ventricular hypertrophy in chronic pulmonary hypertension by lipidomics and HILIC
Study SummaryWe analyzed plasma samples from 33 Yucatan pigs belonging to four different experimental models of pulmonary hypertension (PH): M1 chronic postcapillary PH by pulmonary vein banding; M2 chronic PH by aorto-pulmonary shunting; M3: right ventricular pressure overload by pulmonary artery banding, thus without PH; and M0 sham procedure. Briefly, blood samples were collected 8 months after surgery and untargeted lipidomics and HILIC metabolomic analyses were performed for negative and positive polarities. For quality control, 5 QC samples were included in each analysis, iterative MSMS was performed for metabolite annotation. Plasma metabolomic patterns differed among groups, displaying arginine-nitric oxide and histidine deficiency in both PH models (M1 and M2), altered taurine and purine pathways in M2, and lipidomic changes in all three models of pressure overload.
Institute
Universidad CEU San Pablo
Last NameMoran
First NameMaria
AddressUniversidad CEU-San Pablo. Urb. Montepríncipe
Emailmaria.morangarrido@ceu.es
Phone913724769
Submit Date2023-03-23
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2023-05-10
Release Version1
Maria Moran Maria Moran
https://dx.doi.org/10.21228/M8S726
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004229 AN004230 AN004231 AN004232
Analysis type MS MS MS MS
Chromatography type Reversed phase Reversed phase HILIC HILIC
Chromatography system Agilent 1290 Infinity II Agilent 1290 Infinity II Agilent 1290 Infinity II Agilent 1290 Infinity II
Column Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) Agilent InfinityLab Poroshell 120 EC-C18 (100 x 3mm,2.7um) Waters XBridge BEH Amide (100 x 2.1mm,2.5um) Waters XBridge BEH Amide (100 x 2.1mm,2.5um)
MS Type ESI ESI ESI ESI
MS instrument type QTOF QTOF QTOF QTOF
MS instrument name Agilent 6545 QTOF Agilent 6545 QTOF Agilent 6560 Ion Mobility Agilent 6545 QTOF
Ion Mode POSITIVE NEGATIVE NEGATIVE POSITIVE
Units Peak area Peak area Peak area Peak area

MS:

MS ID:MS003976
Analysis ID:AN004229
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:the gas temperature in the ion source was 200 ºC, the flow was 10 L/min, the pressure in the nebulizer was 50 psig, the temperature of the sheath gas was 300 ºC and the flow of the sheath gas was 12 L/min. The voltage of the capillary was set at 3500 V, the nozzle voltage was 0 L/min, the fragmentor was set at 150 V in the 6545 system and at 400 V in the 6560 system, the voltage in the skimmer was 65 V and the OctopoleRFPeak was 750. After data acquisition, the data files were inspected using Agilent MassHunter Qualitative 10. MassHunter Profinder 10 was used for alignment of data, the deconvolution process and peak integration. MassHunter Lipid Annotator was used to assist in the lipid identification process, features were tentatively annotated based on the MS1 data using the online toll CEU Mass Mediator.
Ion Mode:POSITIVE
  
MS ID:MS003977
Analysis ID:AN004230
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:the gas temperature in the ion source was 200 ºC, the flow was 10 L/min, the pressure in the nebulizer was 50 psig, the temperature of the sheath gas was 300 ºC and the flow of the sheath gas was 12 L/min. The voltage of the capillary was set at 3000 V, the nozzle voltage was 0 L/min, the fragmentor was set at 150 V in the 6545 system and at 400 V in the 6560 system, the voltage in the skimmer was 65 V and the OctopoleRFPeak was 750.After data acquisition, the data files were inspected using Agilent MassHunter Qualitative 10. MassHunter Profinder 10 was used for alignment of data, the deconvolution process and peak integration. MassHunter Lipid Annotator was used to assist in the lipid identification process, features were tentatively annotated based on the MS1 data using the online toll CEU Mass Mediator.
Ion Mode:NEGATIVE
  
MS ID:MS003978
Analysis ID:AN004231
Instrument Name:Agilent 6560 Ion Mobility
Instrument Type:QTOF
MS Type:ESI
MS Comments:The gas temperature in the ion source was 225 ºC, the flow was 13 L/min, the pressure in the nebulizer was 35 psig, the temperature of the sheath gas was 350 ºC and the flow of the sheath gas was 12 L/min. The voltage of the capillary was set at 3500 V, the nozzle voltage was 0 L/min, the fragmentor was set at 125 V in the 6545 system and at 400 V in the 6560 system, the voltage in the skimmer was 45 V and the OctopoleRFPeak was 750. After data acquisition, the data files were inspected using Agilent MassHunter Qualitative 10. MassHunter Profinder 10 was used for alignment of data, the deconvolution process and peak integration. Features were tentatively annotated based on the MS1 data using the online toll CEU Mass Mediator.
Ion Mode:NEGATIVE
  
MS ID:MS003979
Analysis ID:AN004232
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:The gas temperature in the ion source was 225 ºC, the flow was 13 L/min, the pressure in the nebulizer was 35 psig, the temperature of the sheath gas was 350 ºC and the flow of the sheath gas was 12 L/min. The voltage of the capillary was set at 3500 V, the nozzle voltage was 0 L/min, the fragmentor was set at 125 V in the 6545 system and at 400 V in the 6560 system, the voltage in the skimmer was 45 V and the OctopoleRFPeak was 750. Features were tentatively annotated based on the MS1 data using the online toll CEU Mass Mediator.
Ion Mode:POSITIVE