MB Sample ID: SA162038

Local Sample ID:FH5_2
Subject ID:SU001798
Subject Type:Invertebrate
Subject Species:Cherax tenuimanus
Taxonomy ID:99755
Weight Or Weight Range:116g-198g
Gender:Male and female

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU001798
Subject Type:Invertebrate
Subject Species:Cherax tenuimanus
Taxonomy ID:99755
Weight Or Weight Range:116g-198g
Gender:Male and female

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
FH5_2SA162038FL019157FemaleSex
FH5_2SA162038FL0191572Timepoint

Collection:

Collection ID:CO001791
Collection Summary:All haemolymph collections for all animals occurred at the same time of day and the animals were handled in the same order on each of the four collection dates. Haemolymph (200mL) was extracted from the ventral sinus of each crayfish using a 21G needle and 1mL syringe inserted into the soft tissue at the base of the 5th pereopod. Haemolymph was added to 2mL Eppendorf tubes preloaded with 600µL LC-MS grade acetonitrile (Optima, Thermo Fisher Scientific, AUS) containing deuterated internal standards (d8- valine, d9 –trimethylamine-N-oxide (TMAO) , d3-leucine, d6-trans-cinnamic acid, d5-tryptophan, 1g/mL) from Cambridge Isotope Laboratories (Cambridge, MA, USA) and stored on ice. Samples were mixed at 1400rpm (Thermal Mixer, Thermo Fisher Scientific, AUS) for 60 seconds at 4°C, then centrifuged (Heraeus Megafuge 8R, Thermo Fisher Scientific, AUS) for 20 minutes (1800  g) at 4°C. After centrifuging, 100µL of supernatant was aliquoted into five separate vials. The samples were then dried using a SpeedVac centrifugal vacuum concentrator (Thermo Fisher Scientific, AUS). The dried samples were stored at -80°C for subsequent metabolomics analysis.
Collection Protocol Filename:EmilyLette_20210225_014138_PR_CO_Methods__Lette_marron.pdf
Sample Type:Hemolymph
Collection Method:aspiration
Collection Location:ventral sinus accessed from soft tissue at base of 5th pereopod
Storage Conditions:-80℃
Collection Vials:2mL Eppendorf tubes
Storage Vials:2mL Eppendorf tubes

Treatment:

Treatment ID:TR001811
Treatment Summary:Cherax tenuimanus (n=10) were housed in aquaria as individuals prior to sampling at timepoint 1. After timepoint 1 they were placed in pairs with a potential mate of the opposite sex and housed in aquaria over the next four weeks which included timepoints 2-4.

Sample Preparation:

Sampleprep ID:SP001804
Sampleprep Summary:The dried haemolymph samples were reconstituted using 100µL of LC-MS water containing 0.1% Formic acid. Samples were manually swirled, then placed in a thermomixer for 2 minutes at 4oC, before being centrifuged at (1800  g) for 5 minutes at 4oC. Next, 40µL of the supernatant was transferred into LC-MS amber vials with inserts and placed in the autosampler kept at 6oC. The order in which samples were analysed was randomised to avoid any potential instrument bias. A pooled quality control (QC) sample was prepared by adding 40 µL from each reconstituted sample to a single Eppendorf tube, which was then mixed to homogenise in a thermal mixer and centrifuged as above. This pooled sample was aliquoted (40µL) into LC-MS amber vials to create 16 QC samples and placed into the autosampler tray kept at 6°C ready for analysis. Samples were analysed within 24 hours from preparation. At the start of the analytical batch, a solvent blank, matrix blank, and ten conditioning QC samples were analysed (Broadhurst et al., 2018). QC samples were then injected after every fifth marron haemolymph sample with two QCs analysed at the end of the batch, following the standard protocols for metabolomics (Broadhurst et al., 2018).
Processing Storage Conditions:Described in summary

Combined analysis:

Analysis ID AN002804 AN002805
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Thermo Dionex Ultimate 3000 RS Thermo Dionex Ultimate 3000 RS
Column Thermo Hypersil GOLD C18 (100 x 2.1mm,1.9m) Thermo Hypersil GOLD C18 (100 x 2.1mm,1.9m)
MS Type ESI ESI
MS instrument type Orbitrap Orbitrap
MS instrument name Thermo Q Exactive Orbitrap Thermo Q Exactive Orbitrap
Ion Mode POSITIVE NEGATIVE
Units peak area values peak area values

Chromatography:

Chromatography ID:CH002072
Methods Filename:Methods_Lette_marron
Instrument Name:Thermo Dionex Ultimate 3000 RS
Column Name:Thermo Hypersil GOLD C18 (100 x 2.1mm,1.9m)
Column Temperature:45
Flow Gradient:isocratic at 99% A: 1 min; 50% B:1-2 min; linear increase to 99% B: over 7min; 99% B: 2min; initial conditions returned over 2 min; 100% A: 3 min.
Flow Rate:0.3mL/min
Solvent A:100% water; 0.1% formic acid
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS002599
Analysis ID:AN002804
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full scans with data-dependent tandem mass spectrometry were acquired on the Orbitrap mass analyzer. Full scans were acquired at a resolution of 70,000 at mass-to-charge ratio (m/z) 200 over the m/z range 70–1000 with the ESI conditions as follows: source heater = 350°C, sheath gas = 35 (arbitrary units), auxiliary gas = 10 (arbitrary units), capillary temperature 350°C, ion spray voltage = 3.0 kV (positive ion mode) and 2.5 kV (negative ion mode), S-lens 50%, and automatic gain control = 110¬¬¬-6. Tandem mass spectrometry experiments were performed at a resolution of 17,500 at m/z 200 on each sample with the higher energy collisional dissociation energy set at 20 eV. Data acquisition was carried out using Xcalibur software (Thermo Fisher Scientific). Before analysis, the Orbitrap was externally calibrated using ready-made calibration solutions (ESI-negative ion calibration and ESI-positive ion calibration solutions) obtained from Thermo Fisher Scientific.
Ion Mode:POSITIVE
Analysis Protocol File:Methods_Lette_marron
  
MS ID:MS002600
Analysis ID:AN002805
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:Full scans with data-dependent tandem mass spectrometry were acquired on the Orbitrap mass analyzer. Full scans were acquired at a resolution of 70,000 at mass-to-charge ratio (m/z) 200 over the m/z range 70–1000 with the ESI conditions as follows: source heater = 350°C, sheath gas = 35 (arbitrary units), auxiliary gas = 10 (arbitrary units), capillary temperature 350°C, ion spray voltage = 3.0 kV (positive ion mode) and 2.5 kV (negative ion mode), S-lens 50%, and automatic gain control = 110¬¬¬-6. Tandem mass spectrometry experiments were performed at a resolution of 17,500 at m/z 200 on each sample with the higher energy collisional dissociation energy set at 20 eV. Data acquisition was carried out using Xcalibur software (Thermo Fisher Scientific). Before analysis, the Orbitrap was externally calibrated using ready-made calibration solutions (ESI-negative ion calibration and ESI-positive ion calibration solutions) obtained from Thermo Fisher Scientific.
Ion Mode:NEGATIVE