Return to study ST002427 main page

MB Sample ID: SA242785

Local Sample ID:Heavy_Pool-P03
Subject ID:SU002516
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Select appropriate tab below to view additional metadata details:


Subject:

Subject ID:SU002516
Subject Type:Human
Subject Species:Homo sapiens
Taxonomy ID:9606

Factors:

Local Sample IDMB Sample IDFactor Level IDLevel ValueFactor Name
Heavy_Pool-P03SA242785FL030397Heavy DansylationTreatment

Collection:

Collection ID:CO002509
Collection Summary:Human plasma was collected and pooled by BioIVT, purchased as lot# HMN654203 and stored at -80 C.
Sample Type:Blood (plasma)
Storage Conditions:-80℃
Collection Vials:K2EDTA

Treatment:

Treatment ID:TR002528
Treatment Summary:Human subject treatment is not part of this experiment.

Sample Preparation:

Sampleprep ID:SP002522
Sampleprep Summary:Protein was precipitated from pooled human plasma with ice cold methanol and centrifugation. Pooled human plasma was split for metabolite tagging with either light or heavy (2 carbon-13) dansyl chloride. Tagged aliquots were recombined at known mixing ratios to generate samples for LC-MS data acquisition and subsequent testing of isotopic labeling analysis software.
Sampleprep Protocol Filename:DansylatedHumanPlasma.pdf

Combined analysis:

Analysis ID AN003950
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive HF hybrid Orbitrap
Ion Mode POSITIVE
Units unitless L/H ratio

Chromatography:

Chromatography ID:CH002924
Chromatography Summary:A Thermo Scientific Vanquish Horizon UHPLC System coupled with a Thermo Scientific Q Exactive HF Orbitrap was used to conduct LC-(+)FTMS analysis. A Waters ACQUITY UPLC BEH C18 (1.7 μm, 2.1 x 100 mm) column was used along with the following mobile phases: (A) 0.1% formic acid in water and (B) 0.1% formic acid in acetonitrile. The gradient was 25% B (0 min), 25% B (1.2 min), 99% B (11.2 min), 99% B (16.2 min), 25% B (16.3 min), and 25% B (19 min) to achieve column equilibration. The column was maintained at 40 ºC with flowrate of 400 μL/min.
Instrument Name:Thermo Vanquish
Column Name:Waters ACQUITY UPLC BEH C18 (100 x 2.1mm,1.7um)
Column Temperature:40
Flow Gradient:25% B (0 min), 25% B (1.2 min), 99% B (11.2 min), 99% B (16.2 min), 25% B (16.3 min), 25% B (19 min)
Flow Rate:400 uL/min
Solvent A:100% water, 0.1% formic acid
Solvent B:100% acetonitrile, 0.1% formic acid
Chromatography Type:Reversed phase

MS:

MS ID:MS003685
Analysis ID:AN003950
Instrument Name:Thermo Q Exactive HF hybrid Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:A Thermo Scientific Vanquish Horizon UHPLC System coupled with a Thermo Scientific Q Exactive HF Orbitrap was used to conduct LC-(+)FTMS analysis. Ionization for FTMS analysis utilized a HESI source in the positive mode with spray voltage 3 kV, capillary temperature 300 ºC, sheath gas flowrate 35 au, aux gas flowrate 10 au, spare gas flowrate 2 au, max spray current 100 V, probe heater temperature 300 ºC, and S-lens RF level 50 V. FTMS scanning was full MS1 in the range 250 to 1000 m/z with maximum IT 200 ms, AGC target 5x105, and mass resolution 60,000. MS-DIAL v4.9.2 was used to perform peak alignment and annotation. The novel MS-DIAL addon Peak Pair Pruner was used to perform peak pair validation and quantitation with light-to-heavy ratio reporting and corrections for background peaks and isotopic overlap between the light and heavy tags.
Ion Mode:POSITIVE
Capillary Temperature:300 C
Ion Spray Voltage:3000 V
Analysis Protocol File:DansylatedHumanPlasma.pdf