This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000816. The data can be accessed directly via it's Project DOI: 10.21228/M86Q4H This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST001217
Study TitleLCMS untargeted Plasma analysis from COPD subjects
Study SummaryTo use LCMS untargeted metabolomics for the purpose of detecting metabolites in 115 matched BAL and plasma that are associated with COPD
Institute
University of Colorado Anschutz Medical Campus; National Jewish Health
Last NameReisdorph
First NameNichole
Address12850 E Montview Blvd
EmailNichole.Reisdorph@cuanschutz.edu
Phone303-720-9234
Submit Date2019-07-10
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2020-07-15
Release Version1
Nichole Reisdorph Nichole Reisdorph
https://dx.doi.org/10.21228/M86Q4H
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN002029 AN002030
Analysis type MS MS
Chromatography type Reversed phase HILIC
Chromatography system Agilent 6545 Agilent 6520
Column Agilent Zorbax RRHD SB-C18 (100 x 2.1mm,1.8um) Phenomenex Kinetex HILIC 100A (50 x 2.1 mm,2.6um)
MS Type ESI ESI
MS instrument type QTOF QTOF
MS instrument name Agilent 6545 QTOF Agilent 6520 QTOF
Ion Mode POSITIVE POSITIVE
Units Abundance (Log2) Abundance (Log2)

MS:

MS ID:MS001882
Analysis ID:AN002029
Instrument Name:Agilent 6545 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Agilent 6545 Quadrupole Time-of-Flight mass spectrometer (QTOF-MS) in positive ionization mode with dual AJS ESI source, mass range 50–1700 m/z, scan rate 2.00, gas temperature 300 °C, gas flow 12.0 L/min, nebulizer 35 psi, sheath gas temperature 275°C, skimmer 65 V, capillary voltage 3500 V, fragmentor 120 V, reference masses 121.050873 and 922.009798 (Agilent reference mix). The analysis was replicated for tandem MS of selected compounds using a scan range 50–1700m/z, and 10, 20, and 40 eV collision energies with a 500 ms/spectra acquisition time, 1.3 m/z (narrow) isolation width, and 0.25 minute delta retention time.
Ion Mode:POSITIVE
  
MS ID:MS001883
Analysis ID:AN002030
Instrument Name:Agilent 6520 QTOF
Instrument Type:QTOF
MS Type:ESI
MS Comments:Agilent 6520 QTOF-MS in positive ionization mode with dual ESI source, mass range 50–1700 m/z, scan rate 2.00, gas temperature 325 °C, gas flow 12.0 L/min, nebulizer 30 psi, skimmer 60 V, capillary voltage 4000 V, fragmentor 120 V, reference masses 121.050873 and 922.009798 (Agilent reference mix). The analysis was replicated for tandem MS of selected compounds using a scan range 50–1700m/z, and 10, 20, and 40 eV collision energies with a 500 ms/spectra acquisition time, 1.3 m/z (narrow) isolation width, and 0.25 minute delta retention time.
Ion Mode:POSITIVE