Summary of Study ST002092

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001328. The data can be accessed directly via it's Project DOI: 10.21228/M82978 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Show all samples  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002092
Study TitleAddressing batch effects in large-scale metabolomics with augmented experimental design and meta-analysis
Study SummaryUntargeted LC-MS study conducted using RP and HILIC chromatography on three groups of C. elegans: natural isolates, central metabolism mutants, and UDP-glucuronosyltransferase mutants. An augmented study design, rank transformation of the raw data, strict QA/QC followed by a meta-analysis was used for data analysis.
Institute
University of Georgia - Complex Carbohydrate Research Center
LaboratoryEdison Lab
Last NameGarcia
First NameBrianna
Address315 Riverbend Road
Emailbrianna.garcia@uga.edu
Phone7065424401
Submit Date2022-02-14
Num Groups3
Total Subjects119
Raw Data AvailableYes
Raw Data File Type(s)mzML
Analysis Type DetailLC-MS
Release Date2022-04-04
Release Version1
Brianna Garcia Brianna Garcia
https://dx.doi.org/10.21228/M82978
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003416 AN003417 AN003418
Analysis type MS MS MS
Chromatography type Reversed phase Reversed phase HILIC
Chromatography system Thermo Vanquish Thermo Vanquish Thermo Vanquish
Column Thermo Scientific Accucore C30 (150 x 2.1mm,2.6um) Thermo Scientific Accucore C30 (150 x 2.1mm,2.6um) Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
MS Type ESI ESI ESI
MS instrument type Orbitrap Orbitrap Orbitrap
MS instrument name Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid Thermo Orbitrap ID-X tribrid
Ion Mode POSITIVE NEGATIVE POSITIVE
Units Ranked Peak Height Ranked Peak Height Ranked Peak Height

Chromatography:

Chromatography ID:CH002527
Chromatography Summary:Non-polar extracts were separated using a Vanquish (ThermoFisher Scientific), fitted with a ThermoFisher Scientific Accucore™ C30 UPLC RP column (2.1 x 150 mm, 2.6 µm particle size). The compounds were eluted with the following gradient: 60:40 acetonitrile:water (ACN:H2O) with 10 mM ammonium formate and 0.1% formic acid (mobile phase A) and 90:10 isopropanol:acetonitrile with 10 mM ammonium formate and 0.1% formic acid (mobile phase B) using the following gradient program: 0.0 min 20% B; 1.0 min 60% B; 5.0 min 70% B; 5.5 min 85% B; 8.0 min 90% B; 8.2-10.5 min 100% B; 10.7-12.0 min 20% B. A curve 5 value was set for 0.0 minutes, and a curve 6 for the remainder of the gradient. The flow rate was set at 0.400 mL min-1. The column temperature was set to 50°C, and the injection volume was 2 µL.
Instrument Name:Thermo Vanquish
Column Name:Thermo Scientific Accucore C30 (150 x 2.1mm,2.6um)
Column Temperature:50
Solvent A:40% water/60% acetonitrile; 0.1% formic acid; 10 mM ammonium formate
Solvent B:90% isopropanol/10% acetonitrile; 0.1% formic acid; 10 mM ammonium formate
Chromatography Type:Reversed phase
  
Chromatography ID:CH002528
Chromatography Summary:Polar extracts were separated using a Vanquish (ThermoFisher Scientific), fitted with a Waters Acquity UPLC BEH Amide column (2.1 x 150 mm, 1.7 µm particle size). The compounds were eluted with the following gradient: 80:20 water:acetonitrile (H2O:ACN) with 10 mM ammonium formate and 0.1% formic acid (mobile phase A) and 100% ACN with 0.1% formic acid (mobile phase B) using the following gradient program: 0.0-0.5 min 95% B; 8.0-9.4 min 40% B; 9.5-11.0 min 95% B. A curve 5 value was set for 0.0 minutes, a curve 6 at 0.5 min, curve 7 at 8.0 min, and a curve 6 for the remainder of the gradient. The flow rate was set at 0.400 mL min-1. The column temperature was set to 40°C, and the injection volume was 2 µL.
Instrument Name:Thermo Vanquish
Column Name:Waters Acquity BEH Amide (150 x 2.1mm,1.7um)
Column Temperature:40
Solvent A:80% water/20% acetonitrile; 0.1% formic acid; 10 mM ammonium formate
Solvent B:100% acetonitrile; 0.1% formic acid
Chromatography Type:HILIC
  logo