Summary of Study ST002893

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001773. The data can be accessed directly via it's Project DOI: 10.21228/M8J420 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002893
Study TitleFolate depletion time-course in MEL cells with analysis for porphyrin metabolites
Study SummaryCulture of MEL cells in RPMI media containing 100 nM folic acid for 0, 1, 2, 4, 6, or 8 days followed my LC-MS targeting porphyrin metabolites. This is a reverse timecourse where all samples are harvested on the same day. Day 0 in 100 nM folic acid indicates 8 days culture in 2,000 nM folic acid.
Institute
Boston Children's Hospital, Harvard Medical School
Departmentpathology
LaboratoryKanarek Lab
Last NameKanarek
First NameNaama
AddressEnders 1116.2, 300 Longwood Ave, Boston, MA 02115
Emailnaama.kanarek@childrens.harvard.edu
Phone6173557433
Submit Date2023-09-28
Num Groups5
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-02-13
Release Version1
Naama Kanarek Naama Kanarek
https://dx.doi.org/10.21228/M8J420
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004752
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 3mm,2.6um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units peak area

Chromatography:

Chromatography ID:CH003584
Chromatography Summary:Sample (5 uL) was injected onto a 2.6 μm, 150 x 3 mm C18 column (Phenomenex, 00F-4462-Y0) equipped with a 3.0 mm safe-guard column (Phenomenex, AJ0-8775). Column compartment was heated to 45 ºC. Porphyrins were separated with a chromatographic gradient at a flow rate of 0.800 ml min−1 as follows: 0–2 min: 5% B; 2-19min: linear gradient from 5% to 95% B; 19-21min: 95% B; 21.1-23min: return to 5% B.
Instrument Name:Thermo Vanquish
Column Name:Phenomenex Kinetex C18 (150 x 3mm,2.6um)
Column Temperature:45
Flow Gradient:linear gradient from 5% to 95% B
Flow Rate:0.8 mL/min
Solvent A:95% water/5% acetonitrile; 0.1% formic acid
Solvent B:5% water/95% acetonitrile; 0.1% formic acid
Chromatography Type:Reversed phase