Summary of Study ST002893

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001773. The data can be accessed directly via it's Project DOI: 10.21228/M8J420 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST002893
Study TitleFolate depletion time-course in MEL cells with analysis for porphyrin metabolites
Study SummaryCulture of MEL cells in RPMI media containing 100 nM folic acid for 0, 1, 2, 4, 6, or 8 days followed my LC-MS targeting porphyrin metabolites. This is a reverse timecourse where all samples are harvested on the same day. Day 0 in 100 nM folic acid indicates 8 days culture in 2,000 nM folic acid.
Institute
Boston Children's Hospital, Harvard Medical School
Departmentpathology
LaboratoryKanarek Lab
Last NameKanarek
First NameNaama
AddressEnders 1116.2, 300 Longwood Ave, Boston, MA 02115
Emailnaama.kanarek@childrens.harvard.edu
Phone6173557433
Submit Date2023-09-28
Num Groups5
Raw Data AvailableYes
Raw Data File Type(s)raw(Thermo)
Analysis Type DetailLC-MS
Release Date2024-02-13
Release Version1
Naama Kanarek Naama Kanarek
https://dx.doi.org/10.21228/M8J420
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN004752
Analysis type MS
Chromatography type Reversed phase
Chromatography system Thermo Vanquish
Column Phenomenex Kinetex C18 (150 x 3mm,2.6um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode POSITIVE
Units peak area

MS:

MS ID:MS004498
Analysis ID:AN004752
Instrument Name:Thermo Q Exactive Orbitrap
Instrument Type:Orbitrap
MS Type:ESI
MS Comments:The mass spectrometer was operated in full-scan, positive ionization mode using a narrow-range scan: 450-700m/z, with an additional tSIM scan for hemin (616.1767 m/z), CoproP (655.2762 m/z), and PPIX (563.2653 m/z). Metabolites were relatively quantified while referencing an in-house library of chemical standards and using TraceFinder 4.1 (Thermo Fisher Scientific, Waltham, MA, USA), with a 5 ppm mass tolerance.
Ion Mode:POSITIVE
  logo