Summary of Study ST000667

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000470. The data can be accessed directly via it's Project DOI: 10.21228/M89G75 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000667
Study TitleDiabetic Microvascular Plasma/Tissue Lipidomics- Comparison
Study TypeMS analysis
Study SummaryDetermining lipid composition of diabetic microvascular complication-prone tissues and comparing tissues levels to plasma levels. Samples are in addition to plasma and kidney tissue samples ran (shotgun lipidomics) in June-July 2014.
Institute
University of Michigan
DepartmentBiomedical Research Core Facilities
LaboratoryMetabolomics core
Last NameKachman
First NameMaureen
Address6300 Brehm Tower, 1000 Wall Street, Ann Arbor, MI 48105-5714
Emailmkachman@med.umich.edu
Phone(734) 232-8175
Submit Date2017-06-05
Num Groups6
Total Subjects12
Raw Data AvailableYes
Raw Data File Type(s)wiff
Analysis Type DetailLC-MS
Release Date2017-12-06
Release Version1
Maureen Kachman Maureen Kachman
https://dx.doi.org/10.21228/M89G75
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001020 AN001021
Analysis type MS MS
Chromatography type Reversed phase Reversed phase
Chromatography system Shimadzu CTO-20A Nexera X2 Shimadzu CTO-20A Nexera X2
Column Waters Acquity HSS T3 (50 x 2.1mm,1.8um) Waters Acquity HSS T3 (50 x 2.1mm,1.8um)
MS Type ESI ESI
MS instrument type Triple TOF Triple TOF
MS instrument name ABI Sciex 5600+ TripleTOF ABI Sciex 5600+ TripleTOF
Ion Mode NEGATIVE POSITIVE
Units peak area normalized peak area normalized

MS:

MS ID:MS000915
Analysis ID:AN001020
Instrument Name:ABI Sciex 5600+ TripleTOF
Instrument Type:Triple TOF
MS Type:ESI
Ion Mode:NEGATIVE
Analysis Protocol File:A004_-_Shotgun_Lipidomics.pdf
  
MS ID:MS000916
Analysis ID:AN001021
Instrument Name:ABI Sciex 5600+ TripleTOF
Instrument Type:Triple TOF
MS Type:ESI
Ion Mode:POSITIVE
Analysis Protocol File:A004_-_Shotgun_Lipidomics.pdf
  logo