Summary of Study ST003042
This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001893. The data can be accessed directly via it's Project DOI: 10.21228/M81F0P This work is supported by NIH grant, U2C- DK119886.
See: https://www.metabolomicsworkbench.org/about/howtocite.php
This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.
Study ID | ST003042 |
Study Title | The metabolomic resetting effect of DY131 in cisplatin-induced AKI |
Study Type | MS |
Study Summary | LC-MS/MS analyses were performed using renal tissues from cisplatin-induced AKI mice with or without DY131 treatment. The data revealed that DY131 alleviated cisplatin-induced mitochondrial dysfunction and energy metabolism disorder, as well as multiple metabolic disorders. |
Institute | Children's Hospital of Nanjing Medical University |
Department | Department of Nephrology, State Key Laboratory of Reproductive Medicine |
Laboratory | Nanjing Key Lab of Pediatrics, Jiangsu Key Laboratory of Pediatrics |
Last Name | Lu |
First Name | Lingling |
Address | Guangzhou Road 72, Nanjing, Jiangsu, 210000, China |
lulingling89tara@163.com | |
Phone | 0086-25-8311-7435 |
Submit Date | 2023-12-21 |
Raw Data Available | Yes |
Raw Data File Type(s) | mzXML |
Analysis Type Detail | LC-MS |
Release Date | 2024-02-08 |
Release Version | 1 |
Select appropriate tab below to view additional metadata details:
Combined analysis:
Analysis ID | AN004990 | AN004991 |
---|---|---|
Analysis type | MS | MS |
Chromatography type | HILIC | HILIC |
Chromatography system | Thermo Fisher Scientific | Thermo Fisher Scientific |
Column | Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) | Waters ACQUITY UPLC BEH Amide (100 x 2.1mm,1.7um) |
MS Type | ESI | ESI |
MS instrument type | Orbitrap | Orbitrap |
MS instrument name | Thermo Q Exactive HF-X Orbitrap | Thermo Q Exactive HF-X Orbitrap |
Ion Mode | POSITIVE | NEGATIVE |
Units | Peak area | Peak area |
MS:
MS ID: | MS004730 |
Analysis ID: | AN004990 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | sheath gas flow rate as 30 Arb, Aux gas flow rate as 25 Arb, capillary temperature 350 ℃, full MS resolution as 60000, MS/MS resolution as 7500, collision energy as 10/30/60 in NCE mode, spray Voltage as 3.6 kV (positive). Metabolites were quantified by relative quantification and expressed by peak area. |
Ion Mode: | POSITIVE |
Analysis Protocol File: | DY131_MS.txt |
MS ID: | MS004731 |
Analysis ID: | AN004991 |
Instrument Name: | Thermo Q Exactive HF-X Orbitrap |
Instrument Type: | Orbitrap |
MS Type: | ESI |
MS Comments: | sheath gas flow rate as 30 Arb, Aux gas flow rate as 25 Arb, capillary temperature 350 ℃, full MS resolution as 60000, MS/MS resolution as 7500, collision energy as 10/30/60 in NCE mode, spray Voltage as -3.2 kV (negative). Metabolites were quantified by relative quantification and expressed by peak area. |
Ion Mode: | NEGATIVE |
Analysis Protocol File: | DY131_MS.txt |