Summary of Study ST000881

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR000611. The data can be accessed directly via it's Project DOI: 10.21228/M8XQ41 This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

This study contains a large results data set and is not available in the mwTab file. It is only available for download via FTP as data file(s) here.

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  |  Perform analysis on untargeted data  
Download mwTab file (text)   |  Download mwTab file(JSON)   |  Download data files (Contains raw data)
Study IDST000881
Study TitleTargeted metabolomics data of leprosy patients with type 1 reaction
Study TypeTargeted MS/MS analysis in retrospective serum samples of leprosy patients with type 1 reaction
Study SummaryTargeted metabolomics-based analyses of pooled sera from 7 patients with T1R were conducted via LC-MS/MS.
Institute
Colorado State University
DepartmentDepartment of Microbiology, Immunology, and Pathology
LaboratoryBelisle
Last NameSilva
First NameCarlos
AddressRampart Road, 1682 Campus Delivery
Emailcadriano@rams.colostate.edu
Phone9702154962
Submit Date2017-08-02
Num Groups2
Total Subjects16
Num Males5
Num Females11
Study Comments2 groups (first group was leprosy patients with type 1 reaction, N=9; and second group was leprosy patients without type 1 reaction, N=7) 5 males (3 were leprosy patients with type 1 reaction and 2 were leprosy patients without type 1 reaction), 11 females (4 were leprosy patients with type 1 reaction and 7 were leprosy patients without type 1 reaction). For this study we used retrospective sera samples.
PublicationsJ Infect Dis. 2017 Feb 1;215(3):431-439. doi: 10.1093/infdis/jiw541.
Raw Data AvailableYes
Raw Data File Type(s)d
Analysis Type DetailLC-MS
Release Date2017-08-02
Release Version1
Carlos Silva Carlos Silva
https://dx.doi.org/10.21228/M8XQ41
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN001437
Analysis type MS
Chromatography type Reversed phase
Chromatography system Agilent 1290
Column Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um)
MS Type ESI
MS instrument type QTOF
MS instrument name Agilent 6510 QTOF
Ion Mode NEGATIVE
Units arbitrary units

Chromatography:

Chromatography ID:CH001008
Chromatography Summary:This analysis was performed only on negative mode. The solvent gradient used for all chromatography was 2% solvent B for 3 min followed by a 15 min linear gradient of 2% to 98% solvent B, which was held for 0.3 min. Then returned to starting conditions over 1.2 min.
Instrument Name:Agilent 1290
Column Name:Waters Xbridge BEH C18 XP (100 x 2.1mm,2.5um)
Column Temperature:50C
Flow Gradient:0.25 mL/min
Flow Rate:0.25 mL/min
Injection Temperature:4C
Sample Injection:20uL
Solvent A:89% water/5% acetonitrile/5% isopropanol; 5 mM ammonium acetate
Solvent B:50% acetonitrile/50% isopropanol; 5 mM ammonium acetate
Capillary Voltage:2.8 kV
Chromatography Type:Reversed phase
  logo