Summary of Study ST001894

This data is available at the NIH Common Fund's National Metabolomics Data Repository (NMDR) website, the Metabolomics Workbench, https://www.metabolomicsworkbench.org, where it has been assigned Project ID PR001192. The data can be accessed directly via it's Project DOI: 10.21228/M8MX3X This work is supported by NIH grant, U2C- DK119886.

See: https://www.metabolomicsworkbench.org/about/howtocite.php

Perform statistical analysis  |  Show all samples  |  Show named metabolites  |  Download named metabolite data  
Download mwTab file (text)   |  Download mwTab file(JSON)
Study IDST001894
Study TitleInvolvement of Mieap in cardiolipin metabolism (part II)
Study SummaryMass spectrometric data of Cardiolipin in Mice kidney (Mieap-WT vs. Mieap-KO), and Mice liver (Mieap-WT vs. Mieap-KO)
Institute
National Cancer Center Japan Research Institute
Last NameIkari
First NameNaoki
Address5-1-1 Tsukiji, Chuo-ku, Tokyo 104-0045, Japan
Emailnikari@ncc.go.jp
Phone+81-3-3542-2511
Submit Date2021-07-30
Analysis Type DetailLC-MS
Release Date2021-08-09
Release Version1
Naoki Ikari Naoki Ikari
https://dx.doi.org/10.21228/M8MX3X
ftp://www.metabolomicsworkbench.org/Studies/ application/zip

Select appropriate tab below to view additional metadata details:


Combined analysis:

Analysis ID AN003075
Analysis type MS
Chromatography type Reversed phase
Chromatography system UltiMate 3000 (Thermo Fisher Scientific)
Column Waters XBridge C18 (150 x 1.0mm,3.5um)
MS Type ESI
MS instrument type Orbitrap
MS instrument name Thermo Q Exactive Orbitrap
Ion Mode NEGATIVE
Units pmol/mg

Chromatography:

Chromatography ID:CH002275
Chromatography Summary:An aliquot of the lower/organic phase was added with an equal volume of methanol before being loaded onto a DEAE-cellulose column (Wako chemical) pre-equilibrated with chloroform. After successive washes with chloroform/methanol (1:1, v/v), the acidic phospholipids were eluted with chloroform/methanol/HCl/water (12:12:1:1, v/v), followed by evaporation to dryness to give a residue, which was resolved in methanol.
Instrument Name:UltiMate 3000 (Thermo Fisher Scientific)
Column Name:Waters XBridge C18 (150 x 1.0mm,3.5um)
Column Temperature:40
Flow Gradient:ratios of 60%/40% (0 min), 40%/60% (1 min), 20%/80% (9 min), 5%/95% (11-30 min), 95%/5% (31-35 min) and 60%/40% (45 min)
Flow Rate:25ul/min
Solvent A:50% isopropanol/10% methanol/40% water; 5 mM ammonium formate;0.05% ammonium hydroxide
Solvent B:100% isopropanol; 5 mM ammonium formate; 0.05% ammonium hydroxide
Chromatography Type:Reversed phase
  logo